产品中心您的位置:网站首页 > 产品中心 > 气相色谱配件 > 通用色谱配件 > GC 柱温箱加速插入套件-用于Agilent

GC 柱温箱加速插入套件-用于Agilent

简要描述:

GC 柱温箱加速插入套件-用于Agilent
Get the same GC separation in less time—use a GC Accelerator kit and the EZGC method translator to accurately convert methods to a scaled-down column .

打印当前页

免费咨询:010-61755520 / 18911849923

发邮件给我们:water@yuweichina.com

分享到:

GC 柱温箱加速插入套件-用于Agilent 6890和7890仪器

  • Get the same GC separation in less time—use a GC Accelerator kit and the EZGC method translator to accurately convert methods to a scaled-down column .

  • Scaled-down methods let you speed up analysis time and increase sample throughput without capital investment.

  • GC Accelerator kit installs easily without damaging the GC column or interfering with the MS interface.

Designed with GC-MS users in mind, the GC Accelerator kit provides a simple way to speed up sample analysis. By reducing oven volume, these inserts allow faster ramp rates to be attained, which reduces oven cycle time and allows for increased sample throughput and more capacity to process rush samples. When faster ramp rates are used, existing methods can be accurately scaled down to smaller, high-efficiency, narrow-bore columns using Restek’s EZGC method translator. With a scaled-down column, a properly translated method, and a GC Accelerator kit, you can obtain the same chromatographic separation—often with greater sensitivity—in a fraction of the time without making a capital investment.

 

订货信息:

GC 柱温箱加速插入套件-用于Agilent 6890和7890仪器

描述货号
GC 柱温箱加速插入套件23849

 

GC Accelerator Use

Installation

  1. Turn off the oven and wait until the oven, inlets, detectors, and MS transfer line have cooled.

  2. Ensure the column and the column hanger are in the back position in the oven

  3. If no detector is in the front position, install the two block inserts in front of the column as shown in Figure 2. If there is a detector in the front position, install the two block inserts in front of the column as shown in Figure 3.

Caution: The block inserts should not touch the analytical column or the MSD source nut (Figure 4).

4. Install the plate insert in the front of the oven so that the front is flush with the edge of the oven (Figure 5).

 

Removal

Turn off the oven and wait until all oven, inlets, detectors, and MS transfer line surfaces have cooled.

Caution: To avoid burns, use the strap to remove the plate insert or wear heat-resistant gloves. The metal fasteners and label tag on the plate insert may still be hot even after the GC oven has cooled down.

  1. Grip the strap on the plate insert and remove it by pulling the bottom edge out first (Figure 6).

  2. 2. Remove the block inserts carefully; do not allow them to contact the column or the MSD source nut.

 

 

北京豫维科技有限公司是国内专业的通用色谱配件厂家,通用色谱配件各种型号都有出售,通用色谱配件价格公正,欢迎广大顾客来电咨询!
网站地图     中福彩票www.soeprafm.com版权所有    关于我们 新闻中心 产品中心 联系我们 管理登陆 访问量:41037

地址:北京市丰台区槐房南路2号院御槐园18号
在线客服
电话
010-61755520
手机
18911849923
友情链接:中福彩票  万喜彩票官网  万喜彩票网  万喜彩票网  万喜彩票  万家彩票平台  万喜彩票网  

免责声明: 本站资料及图片来源互联网文章,本网不承担任何由内容信息所引起的争议和法律责任。所有作品版权归原创作者所有,与本站立场无关,如用户分享不慎侵犯了您的权益,请联系我们告知,我们将做删除处理!